12HX505-FR EnerSys Data Safe

SKU: 12HX505FR Categories: ,

EnerSys Datasafe

ENERSYS DATASAFE® 12HX505-FR BATTERIES

Power Storage Solutions is a premier platinum stocking Distributor for the Datasafe 12HX400 batteries.  We maintain the batteries in a climate controlled environment, then charge and test each unit prior to shipment. The DataSafe® HX top terminal battery range of Valve Regulated Lead Acid (VRLA) batteries has been designed to offer superior solutions for the Information Technology (IT) and Uninterruptible
Power Supply (UPS) markets. DataSafe HX top terminal batteries are the ideal source of power to protect vital systems.

DataSafe HX top terminal batteries incorporate select design features that maximize reliability while ensuring superior performance and an excellent service life.

Gas recombination technology for VRLA batteries has completely changed the concept of standby power. The minimal level of gas evolution allows battery installation in cabinets or on stands, in offices or near main equipment, maximizing space utilization and reducing storage and maintenance costs. DataSafe HX top terminal batteries deliver superior performance.

ENERSYS DATASAFE® 12HX505-FR FEATURES AND BENEFITS

• Flame retardant case and cover(UL94) to meet UL1778
• Self-resealing, flame-arresting vents
• Battery containers and covers are hermetically sealed to provide leak resistance over the life of the product
• Absorbed Glass Mat (AGM) separators – the electrolyte is completely absorbed into the separator
• High performance brass threaded receptacle, bolt terminal or faston terminals
• Increased energy density
• Computer optimized electrochemistry for increased power up to the 15 minute rate to1.67 Volts Per Cell (VPC)
• 100% initial battery capacity
• Classified as non-spillable

12HX505-FR Specifications

  • Voltage: 12 volt
  • Amp Hour:94 AH
  • Watts per Cell: 381 at 15 minute rate to 1.67 VPC
  • Terminal Type: Threaded Receptacle
  • Normal operating temperature range -22F/-30C to 122F/50C
  • Float charging voltage 2.25 – 2.28 Volts per cell at 77F/25C
  • Charging current – can be safely recharged at high current rates
  • Flame retardant case and cover meet UL 1778

12HX505-FR Construction

  • Brass insert with threaded receptacle conductivity and ease of installation.
  • Compression grommet designed for long life.
  • Self-resealing, flame-arresting vents and low pressure non-return valve prevents ingress of atmospheric oxygen.
  • Rugged high performance positive plates designed to resist corrosion and prolong active life.
  • Balanced negative plates ensure optimum recombination efficiency.
  • Thick-wall plastic containers, highly resistant to shock  and vibration. Flame retardant material is the standard offering.
  • Low resistance microporous Absorbed Glass Mat(AGM) separator. The electrolyte is absorbed within this material.

12HX505-FR Installation and Operation

  • Normal operating temperature range: -22°F (-30°C) to 122°F (50°C)
  • Float charging voltage 2.25-2.28 Volts per cell at 77°F (25°C)
  • DataSafe® HX top terminal batteries can be safely recharged at high current rates.
  • DataSafe HX top terminal batteries can be stored for up to six months at 77°F (25°C) before a freshening charge is required. At higher temperatures this timeinterval will be reduced.
  • Torque specifications
    M6 Receptacle - 60 in-lbs (6.8 Nm) ± 5%

Power Storage Solutions Installation and Service for 12HX505-FR

We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.

We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work.

Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.

For More Information from EnerSys Website: EnerSys DataSafe

Additional Information

Weight 103 lbs
Length

13.3

Width

6.8

Height

Units Per Pallet

30

Brand

Enersys

Battery Model

Datasafe HX

Equipment

Batteries

Market

UPS-Data Centers