FNC125H Grid Power Valve Regulated Fiber Nickel Cadmium Battery
HOPPECKE FNC125H FNC HIGH RATE BATTERIES
The grid | power FNC125H is based on the proven Nickel Cadmium fibre structure technology. It therefore withstands the highest shock and vibration stresses and has a long service life and cycle life even under extreme temperature conditions. Due to the integrated low-pressure valve including a flame-resistant degassing port, the oxygen and hydrogen gases produced during charging are recombined with an efficiency of up to 90 %.
The grid | power FNC125H is therefore extremely low-maintenance and water refilling can be extended to an interval of 20 years under optimal conditions. This significantly reduces the maintenance effort and the associated maintenance costs.
The battery is particularly well suited for stationary systems for uninterruptible power supply in the autonomy range between one hour and several days. Here, it can be operated safely even under extreme temperature influences with a long service life and good performance characteristics.
FNC125H FEATURES AND BENEFITS
• The incorporation of a low-pressure valve and a flame arresting vent with the grid | power FNC-VR technology, recombines oxygen and hydrogen gasses inside the cell with up to 90% efficiency
• The grid | power FNC-VR cell technology with liquid electrolyte has significant advantages over other valve regulated battery systems in which only minimal electrolyte reserves are available.
– Large electrolyte reserve to protect against dry out in the case of a charger failure.
– No tendency to thermal runaway. Therefore, the grid | power FNC-VR can be used in a large temperature range.
• No water addition or filling is required over a period of 20 years when operated on float charge at 20°C.
FNC125H APPLICATIONS
• Emergency Power Supply (UPS)
• Fossil Power Plants
• Control Technology
• Transformer Substations
• Safety Lighting
FNC125H TECHNICAL DATA
• Operating temperature range: -50°C to +60°C
• Nominal Capacity: 125 Ah
• Float Charge: 1.40 to 1.45 V/cell
• Boost Charge: 1.50 to 1.70 V/cell
• Water maintenance period 1.40 V/cell: 20 years at 20°C
• Recharge time to 90% available capacity: 7 - 8 hours at normal boost charge voltage
• Low pressure valve
• Cell jar/lid: Translucent Polypropylene, optional opaque flame retardant polypropylene, UL-94 V0
• Jar/Lid seal: Welded, leak proof
• Terminals: Nickel plated steel
• Electrode design: Nickel plated steel tab welded to the fiber structure
• Electrolyte: KOH density = 1.190 kg/l
FNC125H STANDARDS
• IEC-EN-60623
Power Storage Solutions Engineering Services for FNC125H
Our engineering team can help you quickly calculate many values essential for the proper selection of standby battery products We provide expert sizing analysis you need to properly size and select the proper battery. Let our Battery Sizing Specialist ensure you select the correct product for your UPS applications.
This includes the ability to: Select batteries based on complex step loads and generate IEEE-485 Sizing Work Sheets. Select batteries based on constant current loads. Select batteries based on constant power loads. View and customize rating tables. Perform battery run time analysis.
Power Storage Solutions Installation and Service for FNC125H
We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.
We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work.
Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.
When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. Click Here for More Information
For More Information from EnerSys Website: Hoppecke FNC
Additional Information
Weight | 15.2 lbs |
---|---|
Brand | Hoppecke |
Battery Model | FNC |
Equipment | Batteries |
Market | Telecom, UPS Systems |
Length | 4.53 |
Width | 4.80 |
Height |
Hoppecke FNC VRLA Batteries Engineered for the demanding Utility Market. Call Today. Free Quote. Services: Installation, Service